This command allows a 3rd party integration device to trigger
an alarm condition on a EOL hardwired zone defined with any
of the Burglary zone types and many other zone types up to
zone type 26. This command creates a virtual momentary open
condition on the zone as if the EOL hardwired loop had been
physically opened. This requires M1 Version 4.5.23, 5.1.23
or later. Caution: This command cannot create a virtual short
condition and therefore cannot trigger an alarm condition for
zone types that require a short. i.e. Fire zone alarms cannot
be triggered.
Zone Trigger
This command allows a 3rd party integration device to trigger an alarm condition on a EOL hardwired zone defined with any of the Burglary zone types and many other zone types up to zone type 26. This command creates a virtual momentary open condition on the zone as if the EOL hardwired loop had been physically opened. This requires M1 Version 4.5.23, 5.1.23 or later. Caution: This command cannot create a virtual short condition and therefore cannot trigger an alarm condition for zone types that require a short. i.e. Fire zone alarms cannot be triggered.
4.42.1 Zone Trigger (zt)